Functions and Benefits of Cold Plasma
✔ Powerful Antibacterial and Anti-Inflammatory effects: Cold plasma is suitable for treating various skin issues including acne, eczema, and psoriasis.
✔ Deep Disinfection: By utilizing ozone technology cold plasma provides powerful sterilization and environmental purification without the need for chemical agents.
✔ Enhanced Healing: With no heat, irritation, or redness, cold plasma directly soothes the skin and promotes faster recovery.
✔ Post-Treatment Repair: Cold plasma is especially effective and efficient after Fusion Plasma treatments, supporting antibacterial care, inflammation reduction, and accelerated healing. One whole-face treatment with Canta Esthetic takes only 20 minutes, delivering immediate visible results with ongoing improvement. Fast results, no waiting.
Warm Plasma VS. Traditional Fibroblast Plasma Pen
✔ Low-Invasive and Gentle: Compared to traditional plasma pens, warm plasma causes less damage to the epidermis. Its low-energy loss penetrates deeply into the cell layer without causing severe burning sensations.
✔ High Skin Firming Effect: Warm plasma rapidly stimulates collagen production, addressing skin laxity and signs of aging.
✔ Faster Recovery: Warm plasma energy cools quickly, causing minimal discomfort and eliminating the need for extended recovery time.
Warm Plasma Treatment Frequency & Effects
✔ Most customers achieve ideal results after just 1-2 treatments.
✔ Eye lift and skin renewal treatments show visible results after the first session, with continuous improvement lasting up to 90 days.
Post-Treatment Skin Response & Expected Recovery
✔ Mild redness (typically subsides in 2-3 days; for the eye area, it may take 5-7 days)
✔ Slight swelling (more common around the eye area)
✔ No eschar or black scabs form, avoiding the trauma associated with traditional plasma pens
✔ Immediate skin-tightening effect with continuous improvement during the recovery process
Ozone Plasma (Ozone Plasma Technology)
1. Installing the Ozone Plasma Probe: Remove the ozone plasma probe and insert it into the ozone probe adapter. Securely connect the adapter to the probe port.
2. Selecting Mode & Adjusting Power: On the touchscreen, select the Ozone Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every minute to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Diamond Plasma (Diamond Plasma Technology)
1. Installing theDiamond Plasma Probe: Put the Diamond Plasma Probe through the Fixing Chuck and insert it into the Needle Holder. Insert the Needle Holder into the Probe Port and gently secure it with the Fixing Chuck.
2. Selecting Mode& Adjusting Power: On the touchscreen, select the Diamond Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every minute to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Gold Plasma (Gold Plasma Probe)
1. Installing thegold plasma probe: Put the gold plasma probe through the fixing clamp and insert it into the needle holder. Insert the needle holder into the probe port and gently fix it with the fixing clamp.
2. Selecting Mode& Adjusting Power: On the touchscreen, select the Gold Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operation instructions: Press and hold the foot switch to operate the device. Release the foot switch every minute to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Warm Plasma (Warm Plasma Technology)
1. Installingthe Warm Plasma Probe: First, insert the Warm Plasma Probe through the lower part of the Needle Holder (see the figure). Then, insert the Needle Holder into the probe port and gently secure it with the Fixing Clip.
2. SelectingMode & AdjustingPower: On the touch screen select the Warm Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every minute to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Hyper Plasma (Hyper Plasma Technology)
1. Installingthe Hyper Plasma Probe: Remove the Ultra Plasma Probe and insert the Ultra Adapter. Insert the needle into the needle holder, then the adapter, and finally the probe port.
2. SelectingMode & Adjusting Power: On the touch screen select the Hyper Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every 2 minutes to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly. After use, please turn off the device and the gas tank, clean the probe with an alcohol-based disinfectant, and store it after drying.
Scalp Plasma (Scalp Plasma Technology)
1. Installing theScalp Plasma Probe: Take out the Scalp Plasma Probe and insert the Scalp Adapter. Insert the Needle into the Needle Holder, the Adapter, and the Probe Port.
2. Selecting Mode& Adjusting Power: On the touch screen select the Scalp Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operating Instructions: Press and hold the foot switch to operate the device. Release the foot switch every 2 minutes to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Plasma Roller (Plasma Roller Technology)
1. Installing theplasma roller probe: Take out the required plasma roller probe and insert the roller adapter. Connect the probe port through the adapter.
2. Selecting Mode& Adjusting Power: On the touch screen select the Derma Plasma icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operation Instructions: Press and hold the foot switch to operate the device. Release the foot switch every 2 minutes to prevent the device from overheating. After use, turn off the device, clean the probe with an alcohol-based disinfectant, allow it to dry, and store it properly.
Plasma Jet Probe
1. Installing the Plasma Jet Probe: Please remove and connect the Plasma Jet Probe directly to the Probe Port.
2. Selecting Mode& Adjusting Power: On the Touch Screen select the Plasma Jet icon. Once in the application interface, use the up and down arrows to adjust the power level.
3. Operation Instructions: Press and hold the foot switch to operate the device. Release the foot switch every 2 minutes to prevent the device from overheating. After use, please turn off the device and the gas tank, clean the probe with an alcohol-based disinfectant, and store it in a dry place.
All probes must be cleaned with an alcohol-based disinfectant and stored until dry.
To avoid overheating, lift the Foot Switch at the recommended intervals.
After closing the device, store all probes and accessories properly.
Fusion Plasma Care Guidance | Efficient Skin Rejuvenation, Long-Lasting Beauty Effect
Fusion Plasma adopts a non-invasive professional skin care technology to tighten the skin, fade acne scars, even out skin tone, and reduce pigmentation. It functions in effectively improving skin texture and enhancing skin translucency and firmness. It is essential to follow a scientific process after surgery to ensure the maximum effectiveness of treatment and prolong the care results.
Preoperative Preparation to Optimize Treatment Effects
1. Avoid sun exposure: Avoid exposure to the sun for 2-4 weeks before treatment, and avoid tanning, sunbathing, or using tanning spray.
2. Stop using irritating skin care products: To reduce skin irritation, avoid using skin care products containing ingredients such as fruit acids, A acids, salicylic acids, glycolic acids, etc.
3. Postpone other medical beauty projects: Avoid fillers, Botox, microneedles, and PRP within 21 days before treatment, and avoid laser or deep chemical peels within 90 days before treatment.
Post-Operative Care to Ensure Perfect Repair
1. First 24 hours: Avoid applying any skin care products to allow the skin to repair naturally.
2. For the first 5 days, use unique post-operative care products to avoid possible irritation caused by ordinary skin care products.
3. Do not wear makeup for the first 48 hours, keep the skin clean, and avoid friction and contact with pollution sources.
4. First 1 week: Avoid steam, sauna, high-temperature environment, and strenuous exercise to avoid affecting skin healing.
5. Continue for 2-4 weeks: Use SPF30+ sunscreen to avoid UV exposure and prevent pigmentation and spots.
Maintain Long-Term Effects and Rejuvenate Your Skin
After Fusion Plasma treatment, the skin will gradually improve, and the effect can last 6-9 months. Depending on individual differences, some customers may need additional treatments, and each treatment should be separated by at least 4 weeks to ensure that the skin has enough time to repair and enhance the effect.